2-21. HIGH TEMPERATURE 1. Drain the shortening from the frypot.
LIMIT CONTROL
(Electric Units)
(Continued)
2. Remove control panel.
3. Loosen small inside screw nut on capillary tube.
4. Remove capillary bulb from bulb holder inside the frypot.
5. Straighten the capillary tube.
6. Remove larger outside nut that threads into pot wall.
7. Remove the two screws that secure the high limit to the high
limit bracket.
8. Remove the defective control from the control panel area.
9. Insert new control and replace screws.
10. Uncoil capillary tube, starting at control, and insert through
pot fitting.
To avoid electrical shock or other injury, run the capillary
line under and away from all electrical power wires and
terminals. The tube must NEVER be in such a position
where it could accidentally touch the electrical power
terminals.
11. Carefully bend the capillary bulb and tube toward bulb holder
on heating elements.
12. Slip capillary bulb into bulb holder on heating elements.
Pull excess capillary line from pot and tighten nut into frypot
wall.