2-21. HIGH TEMPERATURE
LIMIT CONTROL
(Electric Units)
(Continued)
Be sure capillary bulb of high limit is located behind
capillary bulb of thermostat. Both capillary bulbs
and bulb holders should be positioned as not to interfere
with basket or when cleaning the frypot wall, or damage to
capillary tube could result.
13. With excess capillary line pulled out, tighten smaller nut hand
tight, then ¼ turn with wrench.
14. Replace front panel.
15. Refill with shortening.
2-22. AUTOLIFT
1. Remove electrical power supplied to unit.
ACTUATOR (MOTOR)
REPLACEMENT
(if applicable)
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain shortening from frypot.
3. Remove baskets and using a large, flat-head screwdriver push
the clevis pin through basket hanger. Using pliers,
pull pin from assembly.
4. Remove rear cover.