2-5. COOK/PUMP SWITCH
(Continued)
Replacement
1. With control panel removed, and wires off of the switch,
push in on tabs on the switch to remove from the panel.
2. Replace with new switch, and reconnect wires to switch
following the wiring diagram.
3. Replace the control panel.
2-6. TEMPERATURE PROBE The temperature probe relays the actual shortening temperature
REPLACEMENT to the control. If it becomes disabled, “E06” will show in the
display. Also, if the temperature is out of calibration more than
10°F, or 10°C, the temperature probe should be replaced as
follows:
1. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Drain the shortening from the frypot.
3. Remove the control panel.
4. Using a 1/2" wrench, remove the nut on the compression fitting.
5. Remove the temperature probe from the frypot.
6. Place the nut and new ferrule on the new temperature probe and
insert the temperature probe into the compression fitting until it
extends one-half (1/2) inch (1.3 cm) into the frypot. Use the
temperature probe gauge provided in the temperature probe kit,
to ensure proper placement in frypot. See Figures 2-1 and 2-2.