Model OFG- 391
1-4. ERROR CODES In the event of a control system failure, the digital display will show
an error message which are coded: “E-4”, “E-5”, “E-6”, “E-10”,
“E-15”, “E-20A-D”, “E-41”, “E-46”, “E-47”, “E-48”, “E-70B”,
and “E-92”. A constant tone is heard when an error code is
displayed; and to silence this tone, press any of the product buttons.
DISPLAY CAUSE PANEL BOARD CORRECTION
“E-4” Control board Turn switch to OFF position, then turn switch back to ON;
overheating if display still shows “E-4”, the board is getting too hot; check
for signs of overheating behind the control panel; once panel
cools down, the controls should return to normal; if “E-4”
persists, replace the control
“E-5” Shortening Turn switch to OFF position, then back to ON; if display
overheating shows “E-5”, the heating circuits and temperature probe should
be checked; once the unit cools down, the controls should
return to normal; if “E-5” persists, replace the control
“E-6A” Temperature Turn switch to OFF position, then turn switch back to ON;
probe open if display shows “E-6”, have the temperature probe checked
“E-6B” Temperature Turn switch to OFF position, then turn switch back to ON;
probe shorted if display shows “E-6”, have the temperature probe checked
“E-10” High limit Reset the high limit by manually pushing up on the red reset
button; if the high limit does not reset, the high limit must be
replaced; call Henny Penny’s Service Department
“E-15” Drain switch Close the drain using the drain valve handle; if display still
shows “E-15”, call Henny Penny’s Service Department
“E-20A” Air pressure switch Press the timer button to try the ignition process again; and if
failure (stuck closed) “E-20A” persists, call Henny Penny’s Service Department
“E-20B” Draft fan or Press the Timer button to try the ignition process again; and if
air pressure “E-20B” persists, call Henny Penny’s Service Department
switch failure
(stuck open)
“E-20C” Ignition module Press the Timer button to try the ignition process again; and if
failure “E-20C” persists, call Henny Penny’s Service Department
“E-20D” Modules working Press the Timer button to try the ignition process again; and if
but no ignition “E-20D” persists, call Henny Penny’s Service Department