Henny Penny CW-114 Manuel d'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
Model CW-216/CW-114
Fig. Item
No. No. Description Function
3-9 18 Power Light Illuminates when the power switch is on and the heat and
water system controls are energized; if the power light goes off
during normal operation, this means the water pan hi-limit device
has opened indicating that the unit is out of water
3-9 19 Radiant Heat The infinite regulator is a time proportioning controller; the higher
Infinite Regulator the number set means the radiant heat will be on a greater
percentage of time
3-9 20 Light Switch The light switch is a two-position, two pole switch used to turn the
lights on and off
3-9 21 Light Fuse Holder The fuse holder is a protective device for the lighting circuit; the
fuse is a 15 amp rating and must be replaced by a fuse of the same
size and rating
3-10 22 Float Switch An electro-mechanical sensing device used to automatically control
the water level in the water pan; the sensor can be inactivated by
the water control switch; the sensor illuminates the low water light
when it senses a low water condition
3-11 23 Water Heater The water heater is a flat strip heater which measures approximately
3” wide by 25” long; there are two heaters rated at 1020 watts
each attached to the bottom of the water pan
1107 3-5
3-2. OPERATING CONTROLS (Continued)
3-3. START-UP
Before using, the Henny Penny Display Counter Warmer should
be thoroughly cleaned as indicated in the Shut-down and
Clean-up section of this manual.
1. Move all switches and controls on the cabinet to the OFF
position.
2. Turn on power supply for the cabinet at the main circuit
breaker.
Step 2
Vue de la page 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 24

Commentaires sur ces manuels

Pas de commentaire