Model 500/600
3-6 1207
3-2. OPERATING COMPONENTS
(Continued)
Fig. Item Description Function
No. No.
4 22 Circuit Breakers A protective device which breaks the circuit when the current
(Electric Models Only) exceeds the rated value
5 23 Contactors Relays that route power to the heating elements; one relay is in
(Electric Models Only) series with the high limit, the other one is in series with the controls
5 24 Transformer Reduces the voltage down to accommodatethose components with
low voltage
8 25 High Temperature A control that senses the temperature of the shortening; if the
Limit temperature of the shortening exceeds the safe operating limit, this
control opens and shuts off the heat to the frypot; when the
temperature of the shortening drops to a safe operation limit, the
control must be manually reset by pressing the red reset button,
located under the control panel, behind the door
9 26 Circuit Breaker Opens the electrical circuit, and removes power to elements
(Single Phase